Where are your biggest areas of maintence/repair expenditures?
For which areas do you perform scheduled preventive maintenance?
HVAC 85%
 
Store Equipment 55%
 
Lighting/Relamping 52%
 
Floor care 41%
 
Electrical 41%
 
General Cleaning/Janitorial 37%
 
Landscaping 20%
 
Roof 19%
 
Signage 16%
 
Parking Lot 15%
 
HVAC 89%
 
Floor care 52%
 
Lighting 46%
 
Store Equipment 40%
 
Parking Lot 25%
 
Roof 22%
 
Signage 15%
 
 
 
 
  Total exceeds 100% due to multiple responses
Source Building Owners and Managers Association International, (BOMA)
Electric Power Research Institute (EPRI)
Notes:The U.S Bureau of Censors surveyed lighting energy consumption in buildings show 30% to 45% in 1997.

Luminance Criteria of IESNA & ANSI

Reduce Direct Glare
To reduce direct glare from luminaires at normal veiwing angles: VISUAL COMFORT PROBABILITY (VCP): 80, MINIMUM

Reduce Indirect Glare
To minimize reflections of the luminaires in the VDT screen (indirect glare)

Viewing Angle
Recommended Limits
Angle Continous Use of Computer
Recommended Limits
Intermitten Use of Computer
55°
850 cd/m2 /250 FL
--
65°
350 cd/m2 /100 FL
850 cd/m2 /250 FL
75°
175 cd/m2 /50 FL
350 cd/m2 /100 FL
85°
--
175 cd/m2 /50 FL
90°
0
0
     
*Measured across, along and 45°
ANSI Ammerican National Standards Institute
IESNA Illumination Engineering Society of North America
 

 

Reduce Contrast
To reduce contrast between the VDT screen and the surrounding area and task: ILLUMINACE: 300-500 LUX (30-50 FOOT-CANDLES), OF AMBIENT LIGHTING. If a higher level is required because of older eyes or very demanding tasks, it should be provided by supplemental task lighting.

Proper Luminance Ratios
Not more than 3:1 between the task and adjacent surfaces; not more than 10:1 between the task and remote surfaces.

Improved
Conventional
Lamping
2-Lamp T8
3-Lamp T8
Efficiency
70%
67%
Spacing Ratio
1.8
1.5
Candelas at Nadir
At 8 X 10 Spacing:
1437 cd
2949 cd
Illuminance
50 fc
71 fc
Power Density 0.8 W/Sq.FL 1.1 W/Sq.FL
Luminance Ratio
Vertical Task/VDT
2.1:1 3.4:1
Horizontal Task/VDT 1.9:1 3.6:1
   
The 2 lamp VP paraboic luminaire performs better than industry standard 3 lamp paraboic troffers for VDT applications. When laid out properly the VP meets the Preferred (continuous use) luminance criteria of ANSVIES RP-1-1993 and provides 33% savings on lighting costs.  

 